Water Source Heat Pumps

Standard Features

• Double wall, vented, 316L stainless steel condenser for safe, potable water heating
• 140°F – 160°F first-pass output temperatures to prevent and eradicate legionella
• Industrial PLC controls, multiple modules can link controls to function as one
• Electronic temperature control and expansion valves
• Integrated stainless steel circulator pump
• 304L stainless steel frame and enclosure
• Stackable for reduced footprint
• 5 sizes available

Available Options

• Skid mounted, fully commissioned systems with storage tanks and controls
• Header assemblies for multiple modules
• Single point electrical distribution for multiple modules
• High Temperature Circuit to produce water up to 185°F
• Compressor VFD for additional operational cost savings
• High Source Circuit for source water temperatures over 85°F
• Double wall, vented, 316L stainless steel evaporator to protect source water (ground water sources or domestic water cooling)
• Secondary heat exchanger loop for working fluids incompatible with standard heat exchangers

 

Air Source Heat Pumps

Standard Features

• Double wall, vented, 316L stainless steel condenser for safe, potable water heating
• 140°F – 160°F first-pass output temperatures to prevent and eradicate legionella
• Industrial PLC controls, multiple modules can link controls to function as one
• Electronic temperature control and expansion valves
• Integrated stainless steel circulator pump
• 304L stainless steel frame and enclosure
• Stackable for reduced footprint
• 5 sizes available

Available Options

• Skid mounted, fully commissioned systems with storage tanks and controls
• Header assemblies for multiple modules
• Single point electrical distribution for multiple modules
• High Temperature Circuit to produce water up to 185°F
• Compressor VFD for additional operational cost savings
• High Source Circuit for source water temperatures over 85°F
• Double wall, vented, 316L stainless steel evaporator to protect source water
(ground water sources or domestic water cooling)
• Secondary heat exchanger loop for working fluids incompatible with standard
heat exchangers

 

Five Reasons Why Building Efficiency Matters

Five Reasons Why Building Efficiency Matters

Greater efficiency in the built environment curbs consumption, supports renewable energy and cuts costs. The built environment in the U.S. is extremely inefficient. Consider these facts: Buildings consume roughly 40 percent of the total energy used in the U.S. and more than 70 percent of the country’s electricity…

BuildingEnergy NYC 2019

BuildingEnergy NYC 2019

The NESEA BuildingEnergy NYC 2019 is a great showcase for solutions building electricifcation throughout the any builidng. For those of you who have attended our session: Tools for Electrification: EVs, Demand Response, Complete Air Barriers, and DHW, or met us at our booth, we thank you for your attendance.

Reinvented Aermec WWM Modular Chiller Transforms NYC Multifamily

Reinvented Aermec WWM Modular Chiller Transforms NYC Multifamily

The conventional chiller installed at a high-rise multifamily condominium in New York City had run the course of its useful life
and it was time for a replacement. However, many challenges existed, including tight equipment spaces, limited budgets, a short
timeline and sustainability concerns.

New York Geothermal Energy Organization Expo 2019 (NY-GEO)

New York Geothermal Energy Organization Expo 2019 (NY-GEO)

In North America, 350 billion Kwh worth of hot water are discarded annually through the drains. In North America and the EU, 87+ billion gallons of wastewater go down the sewers each day, which can replace 1.5 billion Mwh of natural gas consumption. How can wastewater’s thermal…

HIGHMARK | Building Efficiency.  All Rights Reserved. Copyright 2019.